Fibre optic link loss calculator – PON and 1550 nm TV overlay

Enter the fibre length, splices, connectors and splitters between the OLT or EDFA and the receiver, and see the optical loss at each wavelength the system uses, with and without a design margin. PON links are compared with the ITU-T class ranges; the figures are typical planning values, not measurements.

Link loss

1550 nm TV overlay (RF over fibre). Planning values; measured OTDR and power-meter results on the installed plant are what count.

Element1550 nm
Fibre, 5 km1.1 dB
Splices0.4 dB
Connectors1.2 dB
Splitter 1:3217.2 dB
WDM / couplers0.8 dB
Total loss20.7 dB
With 3.0 dB margin23.7 dB
Received power-5.2 dBm
Received, with margin-8.2 dBm
  • At 1550 nm the link loses 20.7 dB (23.7 dB with margin): 17.2 dB is the 1:32 splitter, 1.1 dB is fibre. Received power is inside the receiver's specified optical input range of -15 to 1 dBm.

Coax distribution after the receiver? Coax loss calculator

Fibre attenuation by wavelength

WavelengthUsed bydB per kmdB per 10 km
1270 nmXGS-PON upstream0.373.7
1310 nmGPON upstream, point-to-point Ethernet0.363.6
1490 nmGPON downstream0.252.5
1535 nmNG-PON2 upstream (TWDM channels in the 1524–1544 nm band; 1532–1540 nm narrow band)0.222.2
1550 nmRF video overlay (TV over fibre)0.222.2
1577 nmXGS-PON downstream0.232.3
1600 nmNG-PON2 downstream (TWDM channels in the 1596–1603 nm band)0.252.5

1310 and 1550 nm from a G.657.A2 lead specification; the other wavelengths are typical cabled single-mode values. Cable datasheets quote a maximum per wavelength; installed plant is usually a little better. NG-PON2 is a time- and wavelength-division system: its OLT channels sit on a 100 GHz grid inside the 1596–1603 nm downstream band, and its ONU channels inside the 1524–1544 nm upstream band (wide), 1528–1540 nm (reduced) or 1532–1540 nm (narrow). The calculator uses one representative wavelength per band, 1600 nm and 1535 nm, because fibre attenuation varies by well under 0.01 dB/km across each band.

Optical splitter loss

SplitterIdeal split, 10·log10(N)Maximum insertion loss
1:23.0 dB3.7 dB
1:46.0 dB7.4 dB
1:89.0 dB10.7 dB
1:1612.0 dB13.9 dB
1:3215.1 dB17.2 dB
1:6418.1 dB20.8 dB

A passive splitter divides the light, so each output receives 1/N of the power: 3 dB for 1:2, 15 dB for 1:32, and about 18 dB for 1:64 before any excess. Planar lightwave circuit splitters add a dB or two of excess loss and a uniformity spread between ports, which is why datasheets quote a maximum rather than the ideal: a 1:32 splitter is typically rated at 17.2 dB maximum with about 1.5 dB of port uniformity. The 1:32 splitter is the usual limit because it alone takes 17.2 dB of a 28 dB class B+ budget; a second stage multiplies the ratio (1:4 then 1:8 is 1:32) and the two insertion losses add.

PON optical budget classes

ClassMinimum lossMaximum loss
GPON B+13 dB28 dB
GPON C+17 dB32 dB
XGS-PON N114 dB29 dB
XGS-PON N216 dB31 dB
XGS-PON E118 dB33 dB
XGS-PON E220 dB35 dB
NG-PON2 N114 dB29 dB
NG-PON2 N216 dB31 dB
NG-PON2 E118 dB33 dB
NG-PON2 E220 dB35 dB

Each class defines a range, not just a ceiling. The maximum is the most loss the optics can tolerate at end of life; the minimum is the least loss the receiver can take without being overloaded. A short run through a small splitter can fall below the minimum just as a long one can exceed the maximum, which is why the calculator reports both directions. NG-PON2 (ITU-T G.989.2) reuses the N1, N2, E1 and E2 ranges of XGS-PON, so the same limits apply to both; what differs is the wavelengths, and therefore the fibre loss per kilometre and which direction sets the reach.

The 1550 nm overlay

Broadcast TV over a PON travels as an analogue RF carrier on its own wavelength, 1550 nm, combined onto the same fibre by a WDM coupler and separated again at the home. It is launched from an erbium-doped fibre amplifier at power levels far above the PON downstream, because the RF receiver needs a clean, strong optical signal to recover a broadcast-quality spectrum: a typical distribution EDFA delivers 15.5 dBm per port, and the WDM coupler that combines it with the PON costs about 0.8 dB on both the 1550 nm and the PON wavelengths. For that reason the overlay is not judged against a PON class: the receiver has its own specified input range (-15 to 1 dBm at 1550 nm for the receiver used here), and the calculator compares received power with that range.

With GPON and XGS-PON the overlay sits well clear of the PON wavelengths. NG-PON2's upstream band (1524–1544 nm) ends immediately below the 1550 nm band, which is why G.989.2 defines the reduced (1528–1540 nm) and narrow (1532–1540 nm) upstream options for coexistence with RF video. The calculator applies one pass-through figure per WDM coupler at every wavelength; a coupler's actual loss at the NG-PON2 upstream channels comes from its own datasheet.

How this is calculated

For each wavelength the loss is the fibre length times the attenuation per kilometre, plus a fixed loss per fusion splice, per mechanical splice and per mated connector pair, plus the insertion loss of each splitter stage and each WDM coupler, plus anything you enter as other losses. The design margin is a planning allowance for ageing, repairs and measurement error: it is added when the loss is compared with a class maximum, and left out when it is compared with a class minimum, because the minimum is about the brand-new link being too short. Received power is launch power minus loss.

Common questions about fibre loss

How much loss does a 1:32 splitter add?

About 17.2 dB maximum for a typical planar splitter, against an ideal 15.1 dB. That is well over half of a 28 dB class B+ budget before any fibre, splice or connector is counted.

How far can GPON reach through a 1:32 splitter?

Worked example with the figures on this page: a class B+ budget of 28 dB, less 17.2 dB for the splitter, four fusion splices and four connector pairs, and a 3 dB margin, leaves about 6.2 dB for fibre. At the 1310 nm upstream wavelength, which loses 0.36 dB/km, that is roughly 17 km. The number moves with every input, which is what the calculator is for.

Fusion or mechanical splice, what's the difference in loss?

A fusion splice welds the two fibres and typically loses 0.1 dB or less; a mechanical splice holds them aligned in a gel-filled sleeve and is planned at about 0.3 dB. Over a link with many joints the difference adds up to a connector or two of budget.

Why does 1310 nm lose more than 1550 nm?

Glass scatters shorter wavelengths more strongly, so silica fibre is at its clearest around 1550 nm (0.22 dB/km) and loses more at 1310 nm (0.36 dB/km). Because a PON's upstream sits at the shorter wavelength, the upstream direction usually sets the reach.

Which direction limits an NG-PON2 link?

Usually the downstream. GPON and XGS-PON send upstream at 1310 or 1270 nm, where fibre loses the most, so the upstream sets the reach. NG-PON2 sends upstream around 1535 nm (0.22 dB/km) and downstream around 1600 nm (0.25 dB/km), both near the low-loss part of the curve, so the gap between directions is small and the longer downstream wavelength is the one to watch. The class ranges are the same as XGS-PON.

Is the 1550 nm TV overlay counted in the PON budget?

No. The overlay shares the fibre and the splitters, so it sees the same passive losses, but it is launched from an amplifier at a different power and lands on a different receiver with its own input range. The class ranges apply to the PON wavelengths; the overlay is checked against the receiver's specified input range (-15 to 1 dBm).

Sources: ITU-T G.984.2 (GPON), G.9807.1 (XGS-PON) and G.989.2 (NG-PON2) optical path loss classes and wavelength plans; Manufacturer datasheets for the PLC splitters, SC/APC leads, G.657.A2 fibre, 1550 nm EDFA and 1550 nm optical receiver used in Australian fibre TV distribution; Typical planning values for fusion and mechanical splices, 1:2 and 1:64 splitters, and fibre attenuation at 1270, 1490, 1535, 1577 and 1600 nm. Planning values and ITU-T class ranges; measured OTDR and power-meter results on the installed plant are what count. Reviewed 2026-11-02.