Coax cable and TV splitter loss calculator

Enter the cable run from the antenna, the splitter and each outlet's branch, and see how many dB reach each wall plate at VHF, UHF and satellite IF. The cable figures are manufacturer maximum attenuation at 20 °C; splitter, connector and plate losses are typical values.

Bands
Outlets: splitter to wall plate (metres)

2 of 2 ports in use.

Wall plate

Loss to each outlet

RG6 quad-shield, worst-case frequency per band. Figures are manufacturer maximums at 20 °C.

OutletUHF (694 MHz)
Outlet 115 m + 15 m11.0 dB
Outlet 215 m + 15 m11.0 dB
  • At UHF (694 MHz) the longest run (outlet 1) loses 11.0 dB, of which 5.4 dB is cable and 4.0 dB is the 2-way splitter. Fixed items add 1.6 dB: connectors 0.8 dB, wall plate 0.3 dB and fly lead 0.5 dB.

Working on a fibre TV system? Fibre loss calculator

Cable loss per 10 metres

CableVHF (230 MHz)UHF (694 MHz)Sat IF (2150 MHz)
RG6 quad-shield1.0 dB1.8 dB3.2 dB
RG591.3 dB2.2 dB4.0 dB
RG11 quad-shield0.7 dB1.2 dB2.2 dB

Maximum attenuation at 20 °C from the manufacturer datasheets listed below, interpolated to each band's highest channel.

What a splitter costs you

SplitterIdeal split, 10·log10(N)Typical insertion loss, TVTypical insertion loss, satellite IF
2-way3.0 dB4.0 dB4.8 dB
3-way4.8 dB6.0 dB7.0 dB
4-way6.0 dB7.8 dB9.0 dB
6-way7.8 dB10.5 dB12.0 dB
8-way9.0 dB11.8 dB13.5 dB

Dividing a signal between N outputs costs at least 10·log10(N) dB, because each port can only receive its share of the power: 3 dB for two ways, 6 dB for four, 9 dB for eight. Real splitters lose more than that. The transformer core and the isolation resistors that keep one TV from upsetting another absorb some of the signal, and the loss rises with frequency, which is why the satellite IF column is higher than the TV column for the same unit.

Why UHF loses more than VHF

At radio frequencies current flows only in the outer skin of the centre conductor, and the skin gets thinner as the frequency rises, so the same cable has more resistance at 694 MHz than at 230 MHz. Attenuation grows roughly with the square root of frequency: 10 m of RG6 loses about 1.0 dB at the top of VHF Band III and 1.8 dB at UHF channel 51. A run that leaves plenty of signal for channels 6 to 12 can be marginal for the UHF multiplexes arriving on the same cable, which is why a missing UHF service is often the first sign of a long or ageing run.

A worked UHF example

RG6 quad-shield, 15 m trunk, a 2-way splitter and a 15 m branch, with four F connectors, an F wall plate and a 2 m fly lead:

  • Trunk: 2.7 dB
  • Splitter: 4.0 dB
  • Branch: 2.7 dB
  • Four connectors: 4 × 0.2 = 0.8 dB
  • F wall plate: 0.3 dB
  • 2 m fly lead: 0.5 dB
  • Total, calculated before rounding: 11.0 dB

How this is calculated

For each band the calculator takes the manufacturer attenuation table for the chosen cable and reads it at the band's highest channel (230 MHz for VHF Band III, 694 MHz for UHF channel 51, 2150 MHz for satellite IF), interpolating linearly between the two nearest datasheet frequencies. Loss to an outlet is the trunk length times that figure, plus the splitter insertion loss for the band, plus the branch length times the same figure, plus one fixed loss per connector, the wall plate and the fly lead. Amplifier gain, if you enter one, is subtracted. Entering the signal level at the antenna turns the loss into an estimated level at each outlet.

  • F connectors: count × 0.2 dB.
  • Wall plate: F type 0.3 dB, or PAL 0.8 dB.
  • 2 m fly lead: 0.5 dB when included.

Common questions about coax loss

How much signal does a 2-way or 4-way splitter lose?

A typical 2-way TV splitter loses about 4.0 dB on each output and a 4-way about 7.8 dB, against ideal figures of 3.0 and 6.0 dB. Every output loses the same amount whether or not a TV is connected to the others, and an unused port left open rather than terminated can add reflections on top.

How far can RG6 run before it matters?

There is no fixed distance, because what matters is the level that arrives at the antenna minus everything lost on the way to the TV. The arithmetic is simple: RG6 quad-shield loses about 1.8 dB per 10 m at UHF, so a 30 m run costs about 5.4 dB before any splitter. Whether that leaves enough depends on the signal at the roof, which is why the calculator lets you enter it.

RG6 or RG59, what's the difference in loss?

RG59 has a thinner centre conductor and loses about 2.2 dB per 10 m at UHF against 1.8 dB for RG6 quad-shield, roughly 23% more. RG11 goes the other way, about 35% less than RG6 at the same frequency, at the cost of a stiffer, heavier cable.

Does cable loss affect digital TV picture quality?

Not in the way it affected analogue. A digital receiver decodes a perfect picture as long as the signal stays above its threshold with enough margin for noise, then fails to blocking and drop-outs. Cable loss does not soften the picture; it moves that cliff closer, so a system can look perfect in fine weather and break up when rain or a degraded connector takes the last few dB.

Sources: Matchmaster 06MM-E6Q (RG6 quad-shield) and 06MM-SDI (RG59) datasheets, maximum attenuation dB/100 m at 20 °C; Aerial Industries RG6 quad-shield datasheet (1750 MHz point); Typical insertion losses for RG11 quad-shield, TV splitters, F connectors, wall plates and fly leads. Figures are manufacturer maximum attenuation at 20 °C and typical component losses; real cable, connectors and age vary, and measurements taken on site will differ. Reviewed 2026-11-02.