Every metre of coaxial cable, every splitter port and every connector between the antenna and the TV takes a slice of the signal. The slices are small on their own and add up quickly, and they add up faster at UHF than at VHF. Our new coax loss calculator adds them for you: describe the run from the antenna to each outlet and it reports the loss in decibels, outlet by outlet, at the frequencies Australian TV actually uses.
It is a calculator, not an adviser. It does not tell you which cable or splitter to buy, and it does not judge whether the level at a wall plate is enough. It shows the arithmetic, so the numbers a technician quotes, or the ones on a datasheet, stop being abstract.
What you enter
- Band. VHF (calculated at 230 MHz), UHF (694 MHz) or satellite IF (2150 MHz). Tick more than one to compare them side by side.
- Cable type. RG6 quad-shield, RG59 or RG11, each with its own attenuation table per 100 m.
- Trunk length. The run from the antenna (or amplifier) to the splitter, in metres.
- Splitter. None, or 2, 3, 4, 6 or 8 ways. A splitter's loss is higher at satellite IF, and the table reflects that.
- Branch lengths. One figure per splitter output, from the splitter to each wall plate.
- Fixed items. The number of F connectors on the path, the wall plate type (F or PAL) and whether a fly lead runs from the plate to the TV.
- Optional. Amplifier gain in dB, and the signal level at the start of the run in dBµV if you have a meter reading.
A worked example
Take a single-storey house with RG6 quad-shield cable: 15 m from the antenna to a 4-way splitter in the roof, then branches of 10, 15, 20 and 25 m to four rooms, an F-type wall plate and a fly lead at each. At UHF the calculator breaks the farthest outlet down like this:
- Trunk, 15 m at 17.9 dB per 100 m: 2.7 dB
- 4-way splitter: 7.8 dB
- Branch, 25 m: 4.5 dB
- Four F connectors: 4 × 0.2 = 0.8 dB
- F-type wall plate: 0.3 dB
- 2 m fly lead: 0.5 dB
- Total to that outlet: 16.5 dB
The nearest room, on the 10 m branch, loses 13.9 dB. Tick VHF as well and the same farthest outlet shows 13.6 dB, because RG6 loses 10.4 dB per 100 m at 230 MHz against 17.9 dB at 694 MHz. The splitter is the single largest item on both bands, which is why an 8-way splitter feeding two rooms wastes signal that a 2-way would keep.

Enter a level at the start of the run and the table adds a dBµV column per outlet: 75 dBµV in, 58.5 dBµV at the far room on UHF in this example. The calculator reports that number and stops there. Whether it is enough depends on the signal quality, the noise and the tuner, which only a meter at the plate can show.
Reading the results
The results table lists every outlet on every band you ticked, with the total loss and, if you entered one, the level. A summary line names the worst outlet per band and the ratio between bands, and a breakdown toggle shows each component. The reference tables further down the page give loss per 10 m for each cable at each band, the splitter figures, and a short explanation of why UHF loses more.
Everything you enter is kept in the page address, so the browser's back button steps through your changes and the copy-link button gives you a URL that reopens the same run. That is the easiest way to send a configuration to someone else.
What it cannot tell you
The figures are typical values from cable and splitter datasheets, not measurements of your installation. Water in a connector, a crushed cable or a corroded splitter can add far more loss than any table predicts, and none of that is visible to a calculator. It also says nothing about signal quality: a strong but reflected signal pixelates just as readily as a weak one. If the arithmetic shows a long run losing most of what the antenna collects, that is a reason to have the installation measured, not a diagnosis.
For the background on cable grades, splitters and plates, read our guide to coaxial cables, splitters and wall plates. If the distribution in your building is fibre rather than coax, the fibre loss calculator covers the optical side.